Title: Response time testing of temperature sensors using loop current step response method

Authors: H.M. Hashemian

Addresses: Analysis and Measurement Services Corporation, AMS 9119 Cross Park Drive, Knoxville, TN 37923, USA

Abstract: The Loop Current Step Response (LCSR) method is used for in-situ response time testing of temperature sensors as installed in an industrial process. This paper presents the theoretical foundation of the LCSR (test theory, LCSR equation and test procedures) and the author's research to validate its use in nuclear power industry applications. The validity of the LCSR method depends on how well the temperature sensor design satisfies LCSR test assumptions, the quality of LCSR data in terms of signal-to-noise ratio, the application of proper sampling parameters for the LCSR data acquisition phase, and the suitability of the algorithms and fitting processes used in the LCSR data analysis stage. In multiple tests the author demonstrated a ±10% agreement between the median values of the response time produced by the plunge and LCSR methods. The plunge test is the standard method for laboratory measurement of the response time of temperature sensors.

Keywords: process instrumentation; dynamic measurements; response time testing; in-situ testing; response time degradation; resistance temperature detectors; loop current step response test; nuclear power plants; NPP: nuclear energy; temperature sensors; sensor design; signal-to-noise ratio; sampling parameters; data acquisition; plunge test.

DOI: 10.1504/IJNEST.2013.052164

International Journal of Nuclear Energy Science and Technology, 2013 Vol.7 No.3, pp.209 - 230

Received: 23 Mar 2012
Accepted: 09 Jul 2012

Published online: 20 Sep 2014 *

Full-text access for editors Full-text access for subscribers Purchase this article Comment on this article