Title: Energetic and exergetic performance analysis of a double pass asymmetric CPC photovoltaic/thermal solar collector suitable for building facade

Authors: Wan Nur Adilah Wan Roshdan; Hasila Jarimi; Adnan Ibrahim

Addresses: Solar Energy Research Institute, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia ' Solar Energy Research Institute, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia ' Solar Energy Research Institute, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia

Abstract: An asymmetric compound parabolic concentrator (CPC) photovoltaic/thermal (ACPC-PV/T) solar collector with a double-pass air channel has the potential to enhance PVT performance for facade applications. Through outdoor experiments, we compared the ACPC-PVT with the symmetric CPC PV/T and conventional flat-type PV/T. The analysis shows ACPC PV/T exhibits superior energetic efficiency by 3.95% and 10.79% compared to symmetric CPC PV/T and conventional flat-type PV/T, respectively. Exergy analysis strengthens these findings, with overall exergy efficiency higher by 3.79% and 20.07%, respectively. Economic evaluation reveals a favourable 6.84-year payback for ACPC PV/T, the lowest among the three.

Keywords: PV/thermal; asymmetric; compound parabolic concentrator; CPC; energy; exergy.

DOI: 10.1504/IJEX.2024.140178

International Journal of Exergy, 2024 Vol.44 No.3/4, pp.311 - 322

Received: 23 Jul 2023
Accepted: 06 Jan 2024

Published online: 27 Jul 2024 *

Full-text access for editors Full-text access for subscribers Purchase this article Comment on this article