Title: Collimator and sapphire filter using for the prompt gamma neutron activation analysis facility: modelling and simulation

Authors: Abdessamad Didi; Hamid Amsil; Khalid Embarch; Hamid Bounouira; Khalid Laraki; Hamid Marah; Hassane Dekhissi

Addresses: National Energy Center of Nuclear Science and Technology, Rabat, Morocco ' National Energy Center of Nuclear Science and Technology, Rabat, Morocco ' National Energy Center of Nuclear Science and Technology, Rabat, Morocco ' National Energy Center of Nuclear Science and Technology, Rabat, Morocco ' National Energy Center of Nuclear Science and Technology, Rabat, Morocco ' National Energy Center of Nuclear Science and Technology, Rabat, Morocco ' Theoretical and Particles Physics and Modelling Laboratory (LPTPM), Department of Physics, Faculty of Sciences, Mohammed Ist University, Oujda, Morocco

Abstract: Safety measures play an important role in ensuring any system, although nuclear systems always require more safeguards than necessary. From this principle comes the importance of this research, which aims to conduct a study of neutron simulations and modelling to ensure safe installation of PGAA devices in the NB1 channel from the TRIGA Research Reactor at the Maamoura Center for Nuclear Studies. During this study, we used the Monte Carlo method using the MCNP6/X code. This study aims to determine the neutron profile, neutron distribution, and secondary gamma rays produced during the passage of the neutron flux in the collimator channel, sapphire and the vacuum channel that is maintained for the immediate neutron activation analysis (PGAA).

Keywords: collimator; neutron flux; PGAA; Monte Carlo; MCNP.

DOI: 10.1504/IJNEST.2020.112157

International Journal of Nuclear Energy Science and Technology, 2020 Vol.14 No.2, pp.154 - 164

Received: 10 Apr 2020
Accepted: 29 Aug 2020

Published online: 04 Jan 2021 *

Full-text access for editors Full-text access for subscribers Purchase this article Comment on this article