Performance analysis of different configurations of heating and cooling for a multi-zone building
by Saba Arif; Muzaffar Ali; Anam Nadeem; Kiran Nadeem; Burhan Ali; Roman Kalvin
International Journal of Renewable Energy Technology (IJRET), Vol. 9, No. 3, 2018

Abstract: Multi-zone HVAC designing is important as the considerable amount of the world's energy is used for heating, ventilation, and air conditioning (HVAC) systems. Hospitals are one of the most critical multi-zone buildings. So, proper designing of multi-zone building will lead toward high savings in energy in this sector. Most common types of configurations are; constant volume with reheat (CVHr), dual duct (DD), and variable air volume (VAV) system. The key objective of the current research is to investigate the impact of operational zoning and HVAC system operation strategies on energy performance of a hospital by maintaining the desired comfort conditions. The hospital building is divided into five zones including ward, pharmaceutical, office and OT. The building load is calculated for each zone and optimised for creating the multi-zone building that resulted 52 ton. Then after proper designing of central system based on absorption cooling system to achieve this load, different air distribution system configurations are designed for each zone to determine required air flow rate in terms of cubic fit per min (CFMs). Afterwards, energy simulations are used by developing different models in TRACE 700 for forecasting the best air distribution system for each zone. The results show that COP of absorption chiller is 0.78. Additionally, the economic and cooling capacity analysis of each configuration in terms of net present value (NPV) resulted that the dual duct configuration in most efficient manner for multi-zone buildings such as hospitals.

Online publication date: Wed, 04-Jul-2018

The full text of this article is only available to individual subscribers or to users at subscribing institutions.

 
Existing subscribers:
Go to Inderscience Online Journals to access the Full Text of this article.

Pay per view:
If you are not a subscriber and you just want to read the full contents of this article, buy online access here.

Complimentary Subscribers, Editors or Members of the Editorial Board of the International Journal of Renewable Energy Technology (IJRET):
Login with your Inderscience username and password:

    Username:        Password:         

Forgotten your password?


Want to subscribe?
A subscription gives you complete access to all articles in the current issue, as well as to all articles in the previous three years (where applicable). See our Orders page to subscribe.

If you still need assistance, please email subs@inderscience.com