Potential energy optimisation in a domestic air to water heat pump
by Stephen Tangwe; Kanzumba Kusakana
International Journal of Exergy (IJEX), Vol. 36, No. 2/3/4, 2021

Abstract: The study focused on the determination of the coefficient of performance (COP), exergy losses of an air to water heat pump (AWHP) and presented opportunities for optimisation. Controlled volumes of 150, 50 and 100 L were drawn off from the AWHP at different interval per day for a year. The results depicted that the average annual-day COP, electrical energy consumed and thermal energy gained, were 3.033, 3.625 kWh and 10.996 kWh, respectively. The rate of exergy loss at the evaporator, compressor, condenser and expansion valve were 11.63, 41.89, 18.90 and 27.58%.

Online publication date: Wed, 03-Nov-2021

The full text of this article is only available to individual subscribers or to users at subscribing institutions.

 
Existing subscribers:
Go to Inderscience Online Journals to access the Full Text of this article.

Pay per view:
If you are not a subscriber and you just want to read the full contents of this article, buy online access here.

Complimentary Subscribers, Editors or Members of the Editorial Board of the International Journal of Exergy (IJEX):
Login with your Inderscience username and password:

    Username:        Password:         

Forgotten your password?


Want to subscribe?
A subscription gives you complete access to all articles in the current issue, as well as to all articles in the previous three years (where applicable). See our Orders page to subscribe.

If you still need assistance, please email subs@inderscience.com